Schneider Electric Acti9 iC60N A9F74602 MCB 1P+N 2 A C curve
- Manufacturer part no.
- EAN
- Series
- Acti9 iC60
Ordering
- Order unit
- piece
Description
The Schneider Electric Acti9 iC60N A9F74602 is a low-voltage miniature circuit breaker (MCB) that protects circuits against short circuits and overloads. It has a 1P+N configuration with 1 protected pole, a rated current of 2 A and a C trip curve. Its ultimate short-circuit breaking capacity (Icu) is 50 kA from 220 V AC to 240 V AC according to EN/IEC 60947-2. Its rated short-circuit breaking capacity (Icn) is 6000 A at 230 V AC according to EN/IEC 60898-1. The VisiTrip indicator shows which circuit has tripped, reducing response time. The green VisiSafe strip confirms that the contacts are physically open for downstream maintenance. The fast closing mechanism operates independently of manual action to extend service life. Electrical endurance is up to 10 000 cycles and mechanical endurance is up to 20 000 cycles. The rated insulation voltage Ui is 500 V AC. Current limiting class 3 according to EN/IEC 60898-1 helps reduce the cost of downstream circuit protection. The breaker clips onto a DIN rail and occupies 4 increments of 9 mm. It has pollution degree 3 and overvoltage category IV. The white (RAL9003) housing is 36 mm wide, 85 mm high and 78,5 mm deep. The net weight is 0,25 kg. According to IEC 60529, the degree of protection is IP20 for the device and IP40 in a modular enclosure. The operating temperature ranges from -35 °C to 70 °C and the storage temperature from -40 °C to 85 °C.
Technical data
ETIM class: Miniature circuit breaker (MCB) (EC000042)
Measurements
- Built-in depth
- 44.5 mm
- Width in number of modular spacings
- 2
Electrical
- Release characteristic
- C
- Rated current
- 2 A
- Rated voltage
- 230 V
- Rated insulation voltage Ui
- 500 V
- Rated impulse withstand voltage Uimp
- 6 kV
- Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
- 6 kA
- Voltage type
- AC
- Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
- NA kA
- Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
- 50 kA
- Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
- NA kA
- Power loss
- 1.9 W
- Current limiting class
- 3
- Overvoltage category
- 4
Model/type
- Number of poles (total)
- 2
- Number of protected poles
- 1
Other
- Frequency
- 50, 60 Hz
- Pollution degree
- 3
Mounting/installation
- Flush-mounted installation
- No
Options
- Concurrently switching neutral conductor
- Yes
- Additional equipment possible
- Yes
Protection
- Degree of protection (IP)
- IP20
- Explosion-proof
- No
Operating conditions
- Ambient temperature during operating
- -35, 70 °C
Connection
- Connectable conductor cross section multi-wired
- 1, 16 mm²
- Connectable conductor cross section solid-core
- 1, 25 mm²
Logistics
- Country of origin
- France
- Customs tariff number
- 8536201090