The Schneider Electric Acti9 iC60N A9F74602 is a low-voltage miniature circuit breaker (MCB) that protects circuits against short circuits and overloads. It has a 1P+N configuration with 1 protected pole, a rated current of 2 A and a C trip curve. Its ultimate short-circuit breaking capacity (Icu) is 50 kA from 220 V AC to 240 V AC according to EN/IEC 60947-2. Its rated short-circuit breaking capacity (Icn) is 6000 A at 230 V AC according to EN/IEC 60898-1. The VisiTrip indicator shows which circuit has tripped, reducing response time. The green VisiSafe strip confirms that the contacts are physically open for downstream maintenance. The fast closing mechanism operates independently of manual action to extend service life. Electrical endurance is up to 10 000 cycles and mechanical endurance is up to 20 000 cycles. The rated insulation voltage Ui is 500 V AC. Current limiting class 3 according to EN/IEC 60898-1 helps reduce the cost of downstream circuit protection. The breaker clips onto a DIN rail and occupies 4 increments of 9 mm. It has pollution degree 3 and overvoltage category IV. The white (RAL9003) housing is 36 mm wide, 85 mm high and 78,5 mm deep. The net weight is 0,25 kg. According to IEC 60529, the degree of protection is IP20 for the device and IP40 in a modular enclosure. The operating temperature ranges from -35 °C to 70 °C and the storage temperature from -40 °C to 85 °C.

Technical data

ETIM class: Miniature circuit breaker (MCB) (EC000042)

Measurements

Built-in depth
44.5 mm
Width in number of modular spacings
2

Electrical

Release characteristic
C
Rated current
2 A
Rated voltage
230 V
Rated insulation voltage Ui
500 V
Rated impulse withstand voltage Uimp
6 kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
6 kA
Voltage type
AC
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
NA kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
50 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
NA kA
Power loss
1.9 W
Current limiting class
3
Overvoltage category
4

Model/type

Number of poles (total)
2
Number of protected poles
1

Other

Frequency
50, 60 Hz
Pollution degree
3

Mounting/installation

Flush-mounted installation
No

Options

Concurrently switching neutral conductor
Yes
Additional equipment possible
Yes

Protection

Degree of protection (IP)
IP20
Explosion-proof
No

Operating conditions

Ambient temperature during operating
-35, 70 °C

Connection

Connectable conductor cross section multi-wired
1, 16 mm²
Connectable conductor cross section solid-core
1, 25 mm²

Logistics

Country of origin
France
Customs tariff number
8536201090

Documents