Schneider Electric Acti9 iC60N A9F74603 MCB, 1P+N, 3 A, curve C
- Manufacturer part no.
- EAN
- Series
- Acti9 iC60
Ordering
- Order unit
- piece
Description
The Schneider Electric Acti9 iC60N A9F74603 is a low-voltage miniature circuit breaker (MCB) that protects circuits against short circuits and overloads. It has a 1P+N configuration with 1 protected pole, a rated current of 3 A and a C tripping characteristic. Its ultimate short-circuit breaking capacity Icu is 50 kA from 220 V AC to 240 V AC according to EN/IEC 60947-2. Its rated short-circuit breaking capacity Icn is 6000 A at 230 V AC according to EN/IEC 60898-1. The breaker complies with both standards. The VisiTrip indicator identifies the circuit that tripped on a fault and helps shorten response time. The green VisiSafe strip confirms that the contacts are physically open for downstream maintenance. The quick-closing mechanism operates independently of manual action and helps extend service life. Electrical endurance is up to 10 000 cycles and mechanical endurance is up to 20 000 cycles. The rated insulation voltage Ui is 500 V AC. The current limiting class is 3 according to EN/IEC 60898-1. The breaker clips onto a DIN rail and is 4 pitches of 9 mm wide. It is white (RAL9003), measures 36 mm wide, 85 mm high and 78,5 mm deep, and has a net weight of 0,25 kg. The pollution degree is 3 and the overvoltage category is IV. The degree of protection is IP20 and reaches IP40 in a class II modular enclosure according to IEC 60529. The operating temperature range is -35 °C to 70 °C, and the storage temperature range is -40 °C to 85 °C.
Technical data
ETIM class: Miniature circuit breaker (MCB) (EC000042)
Measurements
- Built-in depth
- 44.5 mm
- Width in number of modular spacings
- 2
Electrical
- Release characteristic
- C
- Rated current
- 3 A
- Rated voltage
- 230 V
- Rated insulation voltage Ui
- 500 V
- Rated impulse withstand voltage Uimp
- 6 kV
- Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
- 6 kA
- Voltage type
- AC
- Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
- NA kA
- Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
- 50 kA
- Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
- NA kA
- Power loss
- 2.2 W
- Current limiting class
- 3
- Overvoltage category
- 4
Model/type
- Number of poles (total)
- 2
- Number of protected poles
- 1
Other
- Frequency
- 50, 60 Hz
- Pollution degree
- 3
Mounting/installation
- Flush-mounted installation
- No
Options
- Concurrently switching neutral conductor
- Yes
- Additional equipment possible
- Yes
Protection
- Degree of protection (IP)
- IP20
- Explosion-proof
- No
Operating conditions
- Ambient temperature during operating
- -35, 70 °C
Connection
- Connectable conductor cross section multi-wired
- 1, 16 mm²
- Connectable conductor cross section solid-core
- 1, 25 mm²
Logistics
- Country of origin
- France
- Customs tariff number
- 8536201090