Photo 1 of 2
Messumformer Thermoelement Typ K, 0-600°C/32-112°F, 0-10 V/0-20 mA/4-20 mA
- Manufacturer part no.
- EAN
- Series
- Harmony Analog
Guest price€118.31 / pcexcl. VATMinimum order 1
Checking availability…
Sign in to see your personal priceOrdering
- Order unit
- piece
Description
Harmony Analog. Analogkonverter für Temperatursignale vom Thermoelement Typ K in normierte Analogsignale. Eingangsbereich Sensortemperatur 0 - +600°C. Kaltstellenkompensation integriert. Analogausgang 0-10 V, 0/4-20 mA. Versorgungsspannung 24 VDC. Aufrastbar auf Hutschiene.
Technical data
ETIM class: Isolation amplifier (EC002653)
Electrical
- Type of power supply
- Active
- Rated supply voltage AC
- NA, - V
- Rated supply voltage DC
- 24, 24 V
- Switching voltage
- 10 V
- Switching current
- NA A
- Switching power
- NA VA
- Galvanic separation between supply voltage and all other current circuits
- No
- Power consumption
- NA W
Other
- Rated operating frequency
- NA, - Hz
- Switching frequency
- 100 Hz
- Load
- 500, 500 Ohm
- Load influence
- NA %
- Temperature drift
- NA %/K
- Device construction
- Other
Connection
- Number of input ranges -60 mV ... +60 mV
- 0
- Number of input ranges -100 mV ... +100 mV
- 0
- Number of input ranges -300 mV ... +300 mV
- 0
- Number of input ranges -500 mV ... +500 mV
- 0
- Number of input ranges -1 V ... +1 V
- 0
- Number of input ranges -2 V ... +2 V
- 0
- Number of input ranges -2.5 V ... +2.5 V
- 0
- Number of input ranges -5 V ... +5 V
- 0
- Number of input ranges -10 V ... +10 V
- 0
- Number of input ranges -20 V ... +20 V
- 0
- Number of input ranges 0 mV ... 60 mV
- 0
- Number of input ranges 0 mV ... 100 mV
- 0
- Number of input ranges 0 mV ... 200 mV
- 0
- Number of input ranges 0 mV ... 300 mV
- 0
- Number of input ranges 0 mV ... 500 mV
- 0
- Number of input ranges 0 V ... 1 V
- 0
- Number of input ranges 0 V ... 2 V
- 0
- Number of input ranges 0 V ... 2.5 V
- 0
- Number of input ranges 0 V ... 5 V
- 0
- Number of input ranges 0 V ... 10 V
- 0
- Number of input ranges 0 V ... 20 V
- 0
- Number of input ranges 0 V ... 24 V
- 0
- Number of input ranges 0 V ... 30 V
- 0
- Number of input ranges 1 V ... 5 V
- 0
- Number of input ranges 2 V ... 10 V
- 0
- Number of input ranges +5 V ... -5 V
- 0
- Number of input ranges +10 V ... -10 V
- 0
- Number of input ranges 5 V ... 0 V
- 0
- Number of input ranges 5 V ... 1 V
- 0
- Number of input ranges 10 V ... 0 V
- 0
- Number of input ranges 10 V ... 2 V
- 0
- Number of input ranges 0 mA ... 5 mA
- 0
- Number of input ranges 0 mA ... 10 mA
- 0
- Number of input ranges 0 mA ... 20 mA
- 0
- Number of input ranges 4 mA ... 20 mA
- 0
- Number of input ranges -5 mA ... +5 mA
- 0
- Number of input ranges -10 mA ... +10 mA
- 0
- Number of input ranges -20 mA ... +20 mA
- 0
- Number of input ranges 20 mA ... 0 mA
- 0
- Number of input ranges 20 mA ... 4 mA
- 0
- Number of output ranges -60 mV ... +60 mV
- 0
- Number of output ranges -100 mV ... +100 mV
- 0
- Number of output ranges -300 mV ... +300 mV
- 0
- Number of output ranges -500 mV ... +500 mV
- 0
- Number of output ranges -1 V ... +1 V
- 0
- Number of output ranges -2 V ... +2 V
- 0
- Number of output ranges -2.5 V ... +2.5 V
- 0
- Number of output ranges -5 V ... +5 V
- 0
- Number of output ranges -10 V ... +10 V
- 0
- Number of output ranges -20 V ... +20 V
- 0
- Number of output ranges 0 mV ... 60 mV
- 0
- Number of output ranges 0 mV ... 100 mV
- 0
- Number of output ranges 0 mV ... 200 mV
- 0
- Number of output ranges 0 mV ... 300 mV
- 0
- Number of output ranges 0 mV ... 500 mV
- 0
- Number of output ranges 0 V ... 1 V
- 0
- Number of output ranges 0 V ... 2 V
- 0
- Number of output ranges 0 V ... 2.5 V
- 0
- Number of output ranges 0 V ... 5 V
- 0
- Number of output ranges 0 V ... 10 V
- 1
- Number of output ranges 0 V ... 20 V
- 0
- Number of output ranges 0 V ... 24 V
- 0
- Number of output ranges 0 V ... 30 V
- 0
- Number of output ranges 1 V ... 5 V
- 0
- Number of output ranges 2 V ... 10 V
- 0
- Number of output ranges +5 V ... -5 V
- 0
- Number of output ranges +10 V ... -10 V
- 0
- Number of output ranges 5 V ... 0 V
- 0
- Number of output ranges 5 V ... 1 V
- 0
- Number of output ranges 10 V ... 0 V
- 0
- Number of output ranges 10 V ... 2 V
- 0
- Number of output ranges 0 mA ... 5 mA
- 0
- Number of output ranges 0 mA ... 10 mA
- 0
- Number of output ranges 0 mA ... 20 mA
- 1
- Number of output ranges 4 mA ... 20 mA
- 1
- Number of output ranges -5 mA ... +5 mA
- 0
- Number of output ranges -10 mA ... +10 mA
- 0
- Number of output ranges -20 mA ... +20 mA
- 0
- Number of output ranges 20 mA ... 0 mA
- 0
- Number of output ranges 20 mA ... 4 mA
- 0
- Malfunction message output
- No
- Type of electric connection
- Spring clamp connection
- Construction type of device
- Other
Model/type
- Number of channels
- 1
Options
- Inherently safe according to EN 60947-5-6 NAMUR
- No
- Galvanic separation between inputs
- No
- Galvanic separation between input and output
- No
- Galvanic separation between output to output
- No
Approval/certification
- SIL according to IEC 61508
- None
Measurements
- Height
- 78 mm
- Width
- 25 mm
- Depth
- 80 mm
Operating conditions
- Operating temperature
- 0, 60 °C
Mounting/installation
- Mounting method
- Snap mounting support rail
Protection
- Degree of protection (IP)
- IP20
Logistics
- Net weight
- 0.101 kg
- Country of origin
- Indonesia
- Customs tariff number
- 8543709099
Packaging
| Pack | Quantity | GTIN | Gross weight | Dimensions (L × W × D) |
|---|---|---|---|---|
| piece | 1 | 3389110109054 | 0.101 kg | 85 × 82 × 27 mm |
| carton | 47 | 23389110109058 | 5.245 kg | 400 × 300 × 150 mm |