Schnittstellenmodul SIL, TeSys island Einspeisung Sicherheit
- Manufacturer part no.
- EAN
- Series
- TeSys island
Guest price€156.92 / pcexcl. VATMinimum order 1
Checking availability…
Sign in to see your personal priceOrdering
- Order unit
- piece
Description
TeSys island - Lastmanagementsystem bis 80A. Schnittstellenkarte - Sicherheitsschnittstelle für Sicherheitsschaltungen bis Ple. Anschluss Schraubklemmen, Status LED. Gerätebreite 22,5 mm, für Hutschienenmontage. Schnittstelle zum Anschluss an ein Sicherheitsrelais mit Rückführkreis. TeSys island - Industrie 4.0 optimiertes Lastmanagmentsystem mit IIOT Protokollen.
Technical data
ETIM class: Fieldbus, decentr. periphery - function-/technology module (EC001601)
Electrical
- Supply voltage AC 50 Hz
- NA, - V
- Supply voltage AC 60 Hz
- NA, - V
- Supply voltage DC
- 20.4, 28.8 V
- Voltage type (supply voltage)
- DC
Options
- Number of functions
- 1
- Radio standard Bluetooth
- No
- Radio standard WLAN 802.11
- No
- Radio standard GPRS
- No
- Radio standard GSM
- No
- Mobile communications standard 3G (UMTS)
- No
- IO link master
- No
- System accessory
- Yes
- Function block restart blockage
- No
- Function block automatic reset
- No
- Function block emergency stop
- No
- Function block affirm push button
- No
- Function block 2-hand switching
- No
- Function block operating mode selection
- No
- Frequency measurement
- No
- Rack-assembly possible
- No
Communication
- Number of HW-interfaces industrial Ethernet
- 0
- Number of interfaces PROFINET
- 0
- Number of HW-interfaces RS-232
- 0
- Number of HW-interfaces RS-422
- 0
- Number of HW-interfaces RS-485
- 0
- Number of HW-interfaces serial TTY
- 0
- Number of HW-interfaces parallel
- 0
- Number of HW-interfaces wireless
- 0
- Number of HW-interfaces USB
- 0
- Number of HW-interfaces other
- 2
- With optical interface
- No
- Supporting protocol for EtherCAT
- No
- Supporting protocol for TCP/IP
- No
- Supporting protocol for PROFIBUS
- No
- Supporting protocol for CAN
- No
- Supporting protocol for INTERBUS
- No
- Supporting protocol for ASI
- No
- Supporting protocol for KNX
- No
- Supporting protocol for Modbus
- No
- Supporting protocol for Data-Highway
- No
- Supporting protocol for DeviceNet
- No
- Supporting protocol for SUCONET
- No
- Supporting protocol for LON
- No
- Supporting protocol for PROFINET IO
- No
- Supporting protocol for PROFINET CBA
- No
- Supporting protocol for SERCOS
- No
- Supporting protocol for Foundation Fieldbus
- No
- Supporting protocol for EtherNet/IP
- No
- Supporting protocol for AS-Interface Safety at Work
- No
- Supporting protocol for DeviceNet Safety
- No
- Supporting protocol for INTERBUS-Safety
- No
- Supporting protocol for PROFIsafe
- No
- Supporting protocol for SafetyBUS p
- No
- Supporting protocol for other bus systems
- Yes
Application
- Suitable for counting
- No
- Suitable for weighing
- No
- Suitable for temperature control
- No
- Suitable for welding control
- No
- Suitable for pressure control
- No
- Suitable for NC
- No
- Suitable for electronic positioning
- No
- Suitable for CNC
- No
- Suitable for SSI
- No
- Suitable for incremental data detection
- No
- Suitable for detection absolute value
- No
- Suitable for flux controller
- No
- Suitable for flux measurement
- No
- Suitable for path controller
- No
- Suitable for cam controller
- No
- Suitable for flying saw
- No
- Suitable for multi-axis control
- No
- Suitable for single-axis controller
- No
- Suitable for multi-axis positioning
- No
- Suitable for single-axis positioning
- No
- Suitable for safety functions
- Yes
Setting/control
- Contactor control function block
- Yes
- Function block access control
- No
Model/type
- Function block contactless working protection installation
- No
Protection
- Degree of protection (IP)
- IP20
- Degree of protection (NEMA)
- NA
- Explosion safety category for gas
- None
- Explosion safety category for dust
- None
- Certified for UL hazardous location group E (metal dusts)
- No
Connection
- Fieldbus connection over separate bus coupler possible
- Yes
Mounting/installation
- Suitable for rail mounting
- Yes
- Wall mounting/direct mounting
- No
- Front built-in possible
- No
Approval/certification
- SIL according to IEC 61508
- 2
- Certified for UL hazardous location class I
- No
- Certified for UL hazardous location class II
- No
- Certified for UL hazardous location class III
- No
- Certified for UL hazardous location division 1
- No
- Certified for UL hazardous location division 2
- No
- Certified for UL hazardous location group A (acetylene)
- No
- Certified for UL hazardous location group B (hydrogen)
- No
- Certified for UL hazardous location group C (ethylene)
- No
- Certified for UL hazardous location group D (propane)
- No
- Certified for UL hazardous location group F (carbonaceous dusts)
- No
- Certified for UL hazardous location group G (non-conductive dusts)
- No
Performance
- Performance level according to EN ISO 13849-1
- Level d
Other
- Appendant operation agent (Ex ia)
- No
- Appendant operation agent (Ex ib)
- No
Measurements
- Width
- 25 mm
- Height
- 118 mm
- Depth
- 114 mm
Logistics
- Net weight
- 0.159 kg
- Country of origin
- Indonesia
- Customs tariff number
- 8538909999
Packaging
| Pack | Quantity | GTIN | Gross weight | Dimensions (L × W × D) |
|---|---|---|---|---|
| piece | 1 | 3606489832872 | 0.266 kg | 155 × 135 × 65 mm |
| carton | 16 | 43606489832870 | 5.019 kg | 400 × 300 × 300 mm |
Documents
- Data Sheet - TPRSM001 (PDF)
- Instructions for use (PDF)
- TeSys island System, Installation, and Operation Guide (PDF)
- TeSys island – Quick Start Guide for EcoStruxure Control Expert Classic (PDF)
- Sales brochure (PDF)
- Sales brochure (PDF)
- Declaration of conformity (PDF)
- Declaration EPD (PDF)
- Others (PDF)
- Product data sheet (PDF)