Skip to content
Eltracore
No photo yet

Siemens

SIRIUS Safety Advanced Bundle for protection door and emergency stop monitoring

Manufacturer part no.
EAN
Price on requestAsk us for a quote for this product.

Ordering

Order unit
piece

Description

SIRIUS safety engineering Advanced package consisting of 3SU1100-0AB50-3BA0, 3SU1801-0AA00-0AB1, 3SU1801-0NB00-2AC2, 2 x 3SU1900-0HG10-0AA0, 3SK1122-2AB40, 3SK1220-2AB40, 3RM1107-2AA04, 3ZY1212-1BA00, 3ZY1212-2BA00, 3ZY1212-2FA00, 3SE6315-0BB01, 3SE6310-0BC01, 3SX5601-2GA03. Advanced Bundle for protection door and emergency stop monitoring with safety relay 3SK1 and motor starter 3RM1. Rely on SIRIUS products from Siemens for safety applications. By purchasing this preconfigured safety package at a preferential price, you can implement a standard-compliant Safety application in accordance with SIL 3 / PL e with just one article number. You do not need any software knowledge to fine-tune your application, but can easily program the 3SK1 safety relay using the DIP switches on the front of the device. Circuit diagrams and files for the evaluation of the safety values in the Safety Evaluation Tool are available online without any additional costs. Safety is a SIRIUS business.

Technical data

ETIM class: Device for monitoring of safety-related circuits (EC001449)

Model/type

Model
UN
With detachable clamps
No
With start input
Yes
With muting function
No
With feedback circuit
Yes
Type of safety according to IEC 61496-1
UN

Mounting/installation

Suitable for rail mounting
No

Connection

Type of electric connection
Other
Number of outputs, safety related, undelayed, with contact
UN
Number of outputs, safety related, delayed, with contact
UN
Number of outputs, safety related, undelayed, semiconductors
UN
Number of outputs, safety related, delayed, semiconductors
UN
Number of outputs, signalling function, undelayed, with contact
UN
Number of outputs, signalling function, delayed, with contact
UN
Number of outputs, signalling function, undelayed, semiconductors
UN
Number of outputs, signalling function, delayed, semiconductors
UN

Electrical

Voltage type (supply voltage)
UN
Supply voltage AC 50 Hz
UN V
Supply voltage AC 60 Hz
UN V
Supply voltage DC
UN V
Power consumption
UN W
Type of control voltage 1
UN
Control voltage 1
UN V
Type of control voltage 2
UN
Control voltage 2
UN V
Voltage type (operating voltage)
UN
Operating voltage AC 50 Hz
UN V
Operating voltage AC 60 Hz
UN V
Operating voltage DC
UN V
Rated switch current
UN A

Application

Suitable for monitoring of position switches
Yes
Suitable for monitoring of emergency-stop circuits
Yes
Suitable for monitoring of valves
No
Suitable for monitoring of optoelectronic protection equipment
No
Suitable for monitoring of tactile sensors
No
Suitable for monitoring of magnetic switches
No
Suitable for monitoring of proximity switches
No

Other

Evaluation inputs
UN
Release-delay
UN s

Approval/certification

Stop category according to IEC 60204
UN
SIL according to IEC 61508
3
With approval for BG BIA
Yes
With approval according to UL
Yes
With approval for TÜV
Yes

Performance

Performance level according to EN ISO 13849-1
Level e

Measurements

Width
160 mm
Height
240 mm
Depth
320 mm

Logistics

Net weight
2.091 kg
Country of origin
Germany
Customs tariff number
85371098

Packaging

PackQuantityGTINGross weightDimensions (L × W × D)
packet140476210736682.091 kg330 × 247 × 176 mm