Monitoring relay, analog, phase failure and sequence 3x 160-690 V AC 50 to
- Manufacturer part no.
- EAN
- Series
- SIRIUS 3UG4
Ordering
- Order unit
- piece
Description
!!! product phase-out !!! the preferred successor is 3UG5512-2BR20 phase failure and sequence monitoring 3 x 160...690 V, 2 changeover contacts; analog monitoring relay phase failure and sequence monitoring 3 x 160...690 V 50...60 Hz AC 2 changeover contacts spring-loaded connection system Line monitoring relay SIRIUS 3UG4 for monitoring phase sequence, phase failure and phase asymmetry, e.g. with mobile systems such as A/C compressors, refrigerated containers, construction site compressors or cranes. Worldwide use thanks to international certificates. Different versions enable application-related selection of products. Less space required in the control cabinet thanks to slim design. All versions with removable terminals. In addition to screw terminals, all the devices are also available with spring-type terminals for fast, maintenance-free and vibration-proof connection. Versions with a wide voltage range and without auxiliary voltage can be used in any networks worldwide. The comprehensive range of accessories, such as unit labeling plates, push-in lugs and cover caps, is standardized for all relays. SIRIUS relays - one range for every application.
Technical data
ETIM class: Phase monitoring relay (EC001441)
Connection
- Type of electric connection
- Spring clamp connection
- Number of contacts as normally closed contact
- 0
- Number of contacts as normally open contact
- 0
- Number of contacts as change-over contact
- 2
Model/type
- With detachable clamps
- Yes
Electrical
- External power supply required
- UN
- Voltage type (supply voltage)
- AC
- Supply voltage AC 50 Hz
- 160, 690 V
- Supply voltage AC 60 Hz
- 160, 690 V
- Supply voltage DC
- UN V
- Voltage measuring range
- 160, 690 V
- Voltage type (operating voltage)
- UN
- Operating voltage AC 50 Hz
- UN V
- Operating voltage AC 60 Hz
- UN V
- Operating voltage DC
- UN V
- Rated switch current
- 3 A
Options
- Phase sequence monitoring
- Yes
- Phase failure detection
- Yes
- Function under voltage detection
- No
- Function overvoltage detection
- No
- Phase imbalance monitoring
- No
Setting/control
- Min. adjustable delay-on energization time
- UN s
- Min. adjustable off-delay time
- UN s
Operating conditions
- Max. permitted delay-on energization time
- UN s
- Max. permitted off-delay time
- UN s
Measurements
- Width
- 22.5 mm
- Height
- 94 mm
- Depth
- 91 mm
Logistics
- Net weight
- 0.14 kg
- Country of origin
- Germany
- Customs tariff number
- 85364900
Packaging
| Pack | Quantity | GTIN | Gross weight | Dimensions (L × W × D) |
|---|---|---|---|---|
| packet | 1 | 4011209642553 | 0.14 kg | 99 × 29 × 107 mm |