Skip to content
Eltracore
No photo yet

Siemens

Analog monitoring relay, phase failure and sequence unbalance 20% fixed

Manufacturer part no.
EAN
Price on requestAsk us for a quote for this product.

Ordering

Order unit
piece

Description

!!! product phase-out !!! the preferred successor is 3UG5514-1BR20 phase failure and sequence monitoring adjustable undervoltage analog monitoring relay phase failure and sequence monitoring adjustable undervoltage asymmetry 20% fixed 3 x 160 to 690 V 50 to 60 Hz AC hysteresis 5% fixed delay time 0-20 s 2 changeover contacts screw terminal Network monitoring relay with analog setting SIRIUS 3UG4 for monitoring phase sequence, phase failure and phase asymmetry and/or undervoltage, e.g. with mobile systems such as A/C compressors, refrigerated containers, construction site compressors or cranes. Worldwide use thanks to international certificates. Different versions enable application-related selection of products. Less space required in the control cabinet thanks to slim design. All versions with removable terminals. In addition to screw terminals, all the devices are also available with spring-type terminals for fast, maintenance-free and vibration-proof connection. Versions with a wide voltage range and without auxiliary voltage can be used in any networks worldwide. The comprehensive range of accessories, such as unit labeling plates, push-in lugs and cover caps, is standardized for all relays. SIRIUS relays - one range for every application.

Technical data

ETIM class: Phase monitoring relay (EC001441)

Connection

Type of electric connection
Screw connection
Number of contacts as normally closed contact
0
Number of contacts as normally open contact
0
Number of contacts as change-over contact
2

Model/type

With detachable clamps
Yes

Electrical

External power supply required
UN
Voltage type (supply voltage)
AC
Supply voltage AC 50 Hz
160, 690 V
Supply voltage AC 60 Hz
160, 690 V
Supply voltage DC
UN V
Voltage measuring range
160, 690 V
Voltage type (operating voltage)
UN
Operating voltage AC 50 Hz
UN V
Operating voltage AC 60 Hz
UN V
Operating voltage DC
UN V
Rated switch current
3 A

Options

Phase sequence monitoring
Yes
Phase failure detection
Yes
Function under voltage detection
Yes
Function overvoltage detection
No
Phase imbalance monitoring
Yes

Setting/control

Min. adjustable delay-on energization time
UN s
Min. adjustable off-delay time
UN s

Operating conditions

Max. permitted delay-on energization time
UN s
Max. permitted off-delay time
UN s

Measurements

Width
22.5 mm
Height
92 mm
Depth
91 mm

Logistics

Net weight
0.145 kg
Country of origin
Germany
Customs tariff number
85364900

Packaging

PackQuantityGTINGross weightDimensions (L × W × D)
packet140112096422630.145 kg99 × 29 × 107 mm