Description

!!! product phase-out !!! the preferred successor is 3UG5643-2CS20 digital monitoring relay cos phi and current monitoring from 90 to 690 V AC overshoot and undershoot with internal power supply 50 to 60 Hz AC noise pulses delay 0.1 to 20 s hysteresis for (I) 0.1 to 2 A 2 changeover contacts with or without fault buffer spring-loaded connection system Cos phi monitoring relay with digital setting SIRIUS 3UG4 for monitoring the power factor and active current for overshooting, e.g. in the event of soiled filter systems, or for undershooting, e.g. in the event of a torn V-belt or pump idling. Worldwide use thanks to wide voltage range and international certificates. The relay monitors even small single-phase motors with a no-load current below 0.5 A. Implicit monitoring for cable break and phase failure is also possible. The power factor or active currentmeasuring principle can be selected. Less space required in the control cabinet thanks to slim design. Reliable diagnostics thanks to display of ACTUAL value and status messages. All versions with removable terminals. In addition to screw terminals, all the devices are also available with spring-type terminals for fast, maintenance-free and vibration-proof connection. They are optionally available with IO-Link. The comprehensive range of accessories, such as unit labeling plates, push-in lugs and cover caps, is standardized for all relays. SIRIUS relays - one range for every application.

Technical data

ETIM class: Effective power (cos phi) monitoring relay (EC001443)

Connection

Type of electric connection
Spring clamp connection
Number of contacts as normally closed contact
0
Number of contacts as normally open contact
0
Number of contacts as change-over contact
2

Model/type

With detachable clamps
Yes

Electrical

External power supply required
Yes
Voltage type (supply voltage)
AC
Supply voltage AC 50 Hz
90, 690 V
Supply voltage AC 60 Hz
90, 690 V
Supply voltage DC
UN V
Voltage measuring range
90, 690 V
Current measuring range
0.2, 10 A
Number of phases
1
Voltage type (operating voltage)
AC/DC
Operating voltage AC 60 Hz
90, 690 V
Operating voltage AC 50 Hz
90, 690 V
Operating voltage DC
UN V
Rated switch current
3 A

Other

Rated operating frequency
50, 60 Hz

Setting/control

Adjustable setting value for Cos-Phi
0.1, 0.99
Min. adjustable delay-on energization time
0 s
Min. adjustable off-delay time
0.1 s

Operating conditions

Max. permitted delay-on energization time
99 s
Max. permitted off-delay time
20 s

Measurements

Width
22.5 mm
Height
103 mm
Depth
91 mm

Logistics

Net weight
0.153 kg
Country of origin
Germany
Customs tariff number
85364900

Packaging

PackQuantityGTINGross weightDimensions (L × W × D)
packet140112096651630.153 kg99 × 29 × 107 mm