Skip to content
Eltracore
No photo yet

Siemens

Analog level monitoring 24-240 V AC/DC, 1/2-point, screw terminals

Manufacturer part no.
EAN
Price on requestAsk us for a quote for this product.
Checking availability…

Ordering

Order unit
piece

Description

analog monitoring relay level monitoring resistance monitoring from 0.5 to 500 kohm overshoot and undershoot supply voltage 24 ... 240 V AC/DC, 50 .. 60 Hz 2-step or 1-step control tripping delay 0.5-30 s 1 changeover contact screw terminal Level monitoring relay with analog setting SIRIUS 3UG5 for level monitoring of conductive fluids to protect against overflow, dry running or leakage. Worldwide use thanks to wide voltage supply range and international certificates. Device replacement possible without rewiring, thanks to removable terminals Can be flexibly adapted to various conductive liquids through analog setting of the sensitivity. Upstream or downstream function is selectable By means of the adjustable tripping delay time, it is also possible to compensate for shaft movements. Other resistance sensors can also be connected, e.g. suitable photoresistors, temperature sensors, position encoders based on resistors etc. In addition to screw terminals, all the devices are also available with spring-type terminals for fast, maintenance-free and vibration-proof connection. Available accessories include individually shortenable two-pole and 3-pole wire electrodes for easy mounting from above/below, as well as bow electrodes for installation from the side to allow higher filling levels and minimal space requirements. Additional accessories, such as unit labeling plates, push-in lugs and cover caps, are standardized for all relays. The 3UG5 level monitoring relays replace the well-proven 3UG4 series. SIRIUS relays - one range for every application.

Technical data

ETIM class: (Fill) level monitoring relay (EC001447)

Connection

Type of electric connection
Screw connection
Number of inputs for electrodes
2
Number of contacts as normally closed contact
UN
Number of contacts as normally open contact
UN
Number of contacts as change-over contact
1

Model/type

With detachable clamps
Yes

Electrical

Voltage type (supply voltage)
AC/DC
Supply voltage AC 50 Hz
24, 240 V
Supply voltage AC 60 Hz
24, 240 V
Supply voltage DC
24, 240 V
Voltage type (operating voltage)
AC/DC
Operating voltage AC 50 Hz
24, 240 V
Operating voltage AC 60 Hz
24, 240 V
Operating voltage DC
24, 240 V
Rated switch current
3 A

Setting/control

Min. adjustable operate delay time
UN s
Min. adjustable off-delay time
0.5 s
Response value sensitivity adjustable
Yes

Operating conditions

Max. permitted operate delay time
UN s
Max. permitted off-delay time
30 s

Other

Physical measurement principle
Other

Options

Cascadable
No

Measurements

Width
22.5 mm
Height
100 mm
Depth
90 mm

Logistics

Net weight
0.159 kg
Country of origin
Germany
Customs tariff number
85364900

Packaging

PackQuantityGTINGross weightDimensions (L × W × D)
packet140476211140640.159 kg127 × 111 × 38 mm