Skip to content
Eltracore
No photo yet

Siemens

Line monitoring relay phase failure, phase sequence and asymmetry 2 CO screw terminal

Manufacturer part no.
EAN
Price on requestAsk us for a quote for this product.
Checking availability…

Ordering

Order unit
piece

Description

monitoring relay phase failure, phase sequence and asymmetry monitoring 3x 160-690 V AC, 15-70 Hz 2 changeover contacts screw terminal Line monitoring relay SIRIUS 3UG5 for monitoring phase sequence, phase failure and phase asymmetry, e.g. with mobile systems such as A/C compressors, refrigerated containers, construction site compressors, cranes or photovoltaic systems and wind turbines. Worldwide use thanks to international certificates. Less space required in the control cabinet thanks to slim design. All versions with removable terminals. In addition to screw terminals, all the devices are also available with spring-loaded terminals for fast, maintenance-free and vibration-proof connection. Versions with a wide voltage range and without auxiliary voltage can be used in any networks worldwide. In addition, devices with SIL 1/PL c certification are available. The comprehensive range of accessories, such as unit labeling plates, spare terminals and sealing covers, is standardized for all relays. The 3UG5 line monitoring relays replace the well-proven 3UG4 series. SIRIUS relays - one range for every application.

Technical data

ETIM class: Phase monitoring relay (EC001441)

Connection

Type of electric connection
Screw connection
Number of contacts as normally closed contact
0
Number of contacts as normally open contact
0
Number of contacts as change-over contact
2

Model/type

With detachable clamps
Yes

Electrical

External power supply required
No
Voltage type (supply voltage)
AC
Supply voltage AC 50 Hz
200, 690 V
Supply voltage AC 60 Hz
200, 690 V
Supply voltage DC
UN V
Voltage measuring range
160, 760 V
Voltage type (operating voltage)
AC/DC
Operating voltage AC 50 Hz
690, 690 V
Operating voltage AC 60 Hz
690, 690 V
Operating voltage DC
UN V
Rated switch current
690 A

Options

Phase sequence monitoring
Yes
Phase failure detection
Yes
Function under voltage detection
No
Function overvoltage detection
No
Phase imbalance monitoring
Yes

Setting/control

Min. adjustable delay-on energization time
0.1 s
Min. adjustable off-delay time
0.1 s

Operating conditions

Max. permitted delay-on energization time
UN s
Max. permitted off-delay time
UN s

Measurements

Width
22.5 mm
Height
100 mm
Depth
90 mm

Logistics

Net weight
0.17 kg
Country of origin
Germany
Customs tariff number
85364900

Packaging

PackQuantityGTINGross weightDimensions (L × W × D)
packet140476210998660.17 kg128 × 109 × 33 mm