Line monitoring relay phase failure, phase sequence and asymmetry 2 CO spring-loaded terminal SIL 1/PL c
- Manufacturer part no.
- EAN
- Series
- SIRIUS 3UG5
Ordering
- Order unit
- piece
Description
monitoring relay phase failure, phase sequence and asymmetry monitoring 3x 160-690 V AC, 15-70 Hz 2 changeover contacts spring-loaded terminal SIL 1/PL c Line monitoring relay SIRIUS 3UG5 for monitoring phase sequence, phase failure and phase asymmetry, e.g. with mobile systems such as A/C compressors, refrigerated containers, construction site compressors, cranes or photovoltaic systems and wind turbines. Worldwide use thanks to international certificates. Less space required in the control cabinet thanks to slim design. All versions with removable terminals. In addition to screw terminals, all the devices are also available with spring-loaded terminals for fast, maintenance-free and vibration-proof connection. Versions with a wide voltage range and without auxiliary voltage can be used in any networks worldwide. In addition, devices with SIL 1/PL c certification are available. The comprehensive range of accessories, such as unit labeling plates, spare terminals and sealing covers, is standardized for all relays. The 3UG5 line monitoring relays replace the well-proven 3UG4 series. SIRIUS relays - one range for every application.
Technical data
ETIM class: Phase monitoring relay (EC001441)
Connection
- Type of electric connection
- Spring clamp connection
- Number of contacts as normally closed contact
- 0
- Number of contacts as normally open contact
- 0
- Number of contacts as change-over contact
- 2
Model/type
- With detachable clamps
- Yes
Electrical
- External power supply required
- No
- Voltage type (supply voltage)
- AC
- Supply voltage AC 50 Hz
- 200, 690 V
- Supply voltage AC 60 Hz
- 200, 690 V
- Supply voltage DC
- UN V
- Voltage measuring range
- 160, 760 V
- Voltage type (operating voltage)
- AC/DC
- Operating voltage AC 50 Hz
- 690, 690 V
- Operating voltage AC 60 Hz
- 690, 690 V
- Operating voltage DC
- UN V
- Rated switch current
- 690 A
Options
- Phase sequence monitoring
- Yes
- Phase failure detection
- Yes
- Function under voltage detection
- No
- Function overvoltage detection
- No
- Phase imbalance monitoring
- Yes
Setting/control
- Min. adjustable delay-on energization time
- 0.1 s
- Min. adjustable off-delay time
- 0.1 s
Operating conditions
- Max. permitted delay-on energization time
- UN s
- Max. permitted off-delay time
- UN s
Measurements
- Width
- 22.5 mm
- Height
- 100 mm
- Depth
- 90 mm
Logistics
- Net weight
- 0.156 kg
- Country of origin
- Germany
- Customs tariff number
- 85364900
Packaging
| Pack | Quantity | GTIN | Gross weight | Dimensions (L × W × D) |
|---|---|---|---|---|
| packet | 1 | 4047621099910 | 0.156 kg | 131 × 112 × 33 mm |