Analog monitoring relay 10-600 V AC/DC overshoot/undershoot spring-loaded terminals
- Manufacturer part no.
- EAN
- Series
- SIRIUS 3UG5
Ordering
- Order unit
- piece
Description
analog monitoring relay voltage monitoring from 10 to 690 V AC/DC overshoot and undershoot supply voltage 24 ... 240 V AC/DC, 50 .. 60 Hz 1 changeover contact spring-loaded terminal Analog setting voltage monitoring relay SIRIUS 3UG5 for monitoring voltages for overshooting and undershooting, e.g. for protecting a system from damage, for protecting batteries against deep discharge or for connecting systems as of a specified voltage. Worldwide use thanks to international certificates. The relay is variably adjustable to overshoot, undershoot or window monitoring. Delay times and RESET behavior are freely parameterizable. Less space required in the control cabinet thanks to slim design.Reliable diagnostics due to display of ACTUAL value and status messages. All versions with removable terminals. In addition to screw terminals, all the devices are also available with spring-type terminals for fast, maintenance-free and vibration-proof connection. The devices differ with regard to their power supply (internal or external), optionally with wide voltage range or with IO-Link. The comprehensive range of accessories, such as unit labeling plates, push-in lugs and cover caps, is standardized for all relays. The 3UG5 monitoring relays replace the well-proven 3UG4 series. SIRIUS relays - one range for every application.
Technical data
ETIM class: Voltage monitoring relay (EC001438)
Connection
- Type of electric connection
- Spring clamp connection
- Number of contacts as normally closed contact
- 0
- Number of contacts as normally open contact
- 0
- Number of contacts as change-over contact
- 1
Model/type
- With detachable clamps
- Yes
Electrical
- External power supply required
- No
- Voltage type (supply voltage)
- AC/DC
- Supply voltage AC 50 Hz
- 24, 240 V
- Supply voltage AC 60 Hz
- 24, 240 V
- Supply voltage DC
- 24, 240 V
- Voltage measuring range 1
- 10, 760 V
- Voltage measuring range 2
- UN V
- Type of voltage measuring range
- AC/DC
- Response value voltage
- 10, 760 V
- Single-phase under voltage possible
- Yes
- Three-phase under voltage possible
- No
- Single-phase overvoltage possible
- Yes
- Three-phase overvoltage possible
- No
- Voltage type (operating voltage)
- AC/DC
- Operating voltage AC 50 Hz
- 240, 240 V
- Operating voltage AC 60 Hz
- 240, 240 V
- Operating voltage DC
- 24, 24 V
- Rated switch current
- 3 A
Options
- Single-phase hysteresis possible
- Yes
- Three-phase hysteresis possible
- No
- Contains function DC-under voltage
- Yes
- Contains function DC overvoltage
- Yes
- Contains function DC-voltage hysteresis
- Yes
Setting/control
- Min. adjustable delay-on energization time
- UN s
- Min. adjustable off-delay time
- 0.5 s
Operating conditions
- Max. permitted delay-on energization time
- 30 s
- Max. permitted off-delay time
- 30 s
Measurements
- Width
- 22.5 mm
- Height
- 100 mm
- Depth
- 90 mm
Logistics
- Net weight
- 0.141 kg
- Country of origin
- Germany
- Customs tariff number
- 85364900
Packaging
| Pack | Quantity | GTIN | Gross weight | Dimensions (L × W × D) |
|---|---|---|---|---|
| packet | 1 | 4047621114132 | 0.141 kg | 127 × 111 × 38 mm |