circuit breaker 3VA2 IEC Frame 100 breaking capacity class L Icu=150 kA @ 415 V 4-pole, line protection ETU320, LI, In=100 A overload protection Ir=40 A...100 A short-circuit protection Ii=1.5...12 x In neutral conductor protection adjustable (OFF, 50%, 100%) nut keeper kit Molded case circuit breaker SENTRON 3VA2 for effective line protection with reliable disconnection in the event of overload and short-circuit. The 3VA molded case circuit breakers set new standards in flexibility and the variety of modular accessories available with a small space requirement. The 3VA2 molded case circuit breakers are available in 3- and 4-pole versions with different rated uninterrupted currents for installation in fixed-mounted and plug-in/withdrawable versions. The modular and easy-to-install accessories with a wide range of functions are consistent and uniform for all sizes and series of 3VA molded case circuit breakers. SENTRON 3VA molded case circuit breakers - One system. For all applications.

Technical data

ETIM class: Power circuit-breaker for trafo/generator/installation protection (EC000228)

Electrical

Rated permanent current Iu
100 A
Rated voltage
690, 690 V
Rated short-circuit breaking capacity Icu at 400 V, 50 Hz
150 kA
Overload release current setting
40, 100 A
Adjustment range short-term delayed short-circuit release
UN A
Adjustment range undelayed short-circuit release
150, 1200 A
Power loss
7.7 W
With integrated under voltage release
No
Number of poles
4

Other

Device construction
Built-in device fixed built-in technique

Protection

Integrated earth fault protection
No
Complete device with protection unit
Yes
Degree of protection (IP)
IP40

Connection

Type of electrical connection of main circuit
Screw connection
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Position of connection for main current circuit
Front side

Mounting/installation

Suitable for DIN rail (top hat rail) mounting
Yes
DIN rail (top hat rail) mounting optional
No

Model/type

With switched-off indicator
No
Type of control element
Rocker lever
Motor drive integrated
No

Options

Motor drive optional
Yes

Logistics

Net weight
3.2 kg
Country of origin
Czechia
Customs tariff number
85362090

Packaging

PackQuantityGTINGross weightDimensions (L × W × D)
packet140429488339023.2 kg200 × 169 × 145 mm