Skip to content
Eltracore
No photo yet

Siemens

circuit breaker 3VA6 UL frame 150 3-pole, starter protection ETU310M, I, In=100A without overload protection short-circuit protection Ii=3...15 x I...

Manufacturer part no.
EAN
Price on requestAsk us for a quote for this product.

Ordering

Order unit
piece

Description

circuit breaker 3VA6 UL frame 150 3-pole, starter protection ETU310M, I, In=100A without overload protection short-circuit protection Ii=3...15 x In without connection Molded-case circuit breaker SENTRON 3VA6 with UL approval for effective starter protection for protecting electrical motors against short-circuits. The 3VA5 and 3VA6 molded case circuit breakers set new standards in flexibility and the variety of modular accessories available with a small space requirement. In addition to the IEC standard, the two series also meet the UL standard. All of the functions can thus be used for plants around the world. The 3VA6 molded case circuit breakers are available in 3-pole versions with different rated uninterrupted currents for installation in fixed-mounted as well as in plug-in/withdrawable versions. The modular and easy-to-install accessories with a wide range of functions are consistent and uniform for all sizes and series of 3VA molded case circuit breakers. SENTRON 3VA molded case circuit breakers - One system. For all applications.

Technical data

ETIM class: Power circuit-breaker for trafo/generator/installation protection (EC000228)

Electrical

Rated permanent current Iu
100 A
Rated voltage
690, 690 V
Rated short-circuit breaking capacity Icu at 400 V, 50 Hz
110 kA
Overload release current setting
UN A
Adjustment range short-term delayed short-circuit release
UN A
Adjustment range undelayed short-circuit release
300, 1500 A
Power loss
13 W
With integrated under voltage release
No
Number of poles
3

Other

Device construction
Built-in device fixed built-in technique

Protection

Integrated earth fault protection
No
Complete device with protection unit
Yes
Degree of protection (IP)
IP40

Connection

Type of electrical connection of main circuit
Other
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Position of connection for main current circuit
Other

Mounting/installation

Suitable for DIN rail (top hat rail) mounting
Yes
DIN rail (top hat rail) mounting optional
Yes

Model/type

With switched-off indicator
No
Type of control element
Rocker lever
Motor drive integrated
No

Options

Motor drive optional
Yes

Logistics

Net weight
2.061 kg
Country of origin
Czechia
Customs tariff number
85362090

Packaging

PackQuantityGTINGross weightDimensions (L × W × D)
packet140429488473122.061 kg200 × 134 × 145 mm