circuit breaker 3VA6 UL frame 150 3-pole, starter protection ETU310M, I, In=100A without overload protection short-circuit protection Ii=3...15 x I...
- Manufacturer part no.
- EAN
- Series
- SENTRON 3VA6
Ordering
- Order unit
- piece
Description
circuit breaker 3VA6 UL frame 150 3-pole, starter protection ETU310M, I, In=100A without overload protection short-circuit protection Ii=3...15 x In without connection Molded-case circuit breaker SENTRON 3VA6 with UL approval for effective starter protection for protecting electrical motors against short-circuits. The 3VA5 and 3VA6 molded case circuit breakers set new standards in flexibility and the variety of modular accessories available with a small space requirement. In addition to the IEC standard, the two series also meet the UL standard. All of the functions can thus be used for plants around the world. The 3VA6 molded case circuit breakers are available in 3-pole versions with different rated uninterrupted currents for installation in fixed-mounted as well as in plug-in/withdrawable versions. The modular and easy-to-install accessories with a wide range of functions are consistent and uniform for all sizes and series of 3VA molded case circuit breakers. SENTRON 3VA molded case circuit breakers - One system. For all applications.
Technical data
ETIM class: Power circuit-breaker for trafo/generator/installation protection (EC000228)
Electrical
- Rated permanent current Iu
- 100 A
- Rated voltage
- 690, 690 V
- Rated short-circuit breaking capacity Icu at 400 V, 50 Hz
- 110 kA
- Overload release current setting
- UN A
- Adjustment range short-term delayed short-circuit release
- UN A
- Adjustment range undelayed short-circuit release
- 300, 1500 A
- Power loss
- 13 W
- With integrated under voltage release
- No
- Number of poles
- 3
Other
- Device construction
- Built-in device fixed built-in technique
Protection
- Integrated earth fault protection
- No
- Complete device with protection unit
- Yes
- Degree of protection (IP)
- IP40
Connection
- Type of electrical connection of main circuit
- Other
- Number of auxiliary contacts as normally closed contact
- 0
- Number of auxiliary contacts as normally open contact
- 0
- Number of auxiliary contacts as change-over contact
- 0
- Position of connection for main current circuit
- Other
Mounting/installation
- Suitable for DIN rail (top hat rail) mounting
- Yes
- DIN rail (top hat rail) mounting optional
- Yes
Model/type
- With switched-off indicator
- No
- Type of control element
- Rocker lever
- Motor drive integrated
- No
Options
- Motor drive optional
- Yes
Logistics
- Net weight
- 2.061 kg
- Country of origin
- Czechia
- Customs tariff number
- 85362090
Packaging
| Pack | Quantity | GTIN | Gross weight | Dimensions (L × W × D) |
|---|---|---|---|---|
| packet | 1 | 4042948847312 | 2.061 kg | 200 × 134 × 145 mm |