Skip to content
Eltracore
No photo yet

Siemens

SITOP PSE200U selectivity module, 24 V DC/4 x 0.5-3A w. single-channel signaling

Manufacturer part no.
EAN
Price on requestAsk us for a quote for this product.

Ordering

Order unit
piece

Description

SITOP PSE200U 3 A NEC CLASS 2 selectivity module 4-channel input: 24 V DC/12 A output: 24 V/4x 3 A NEC class 2 threshold value adjustable 0.5-3 A with status message for each output The SITOP PSE200U selectivity module is the optimum enhancement for all 24 V power supplies to distribute the load current to several feeders and to monitor it. Overloads and short-circuits in one or more feeders are detected reliably. The electronics permit brief current peaks caused, for example, by high inrush currents, but disconnect feeders in the event of an extended overload. This is ensured even on high-resistance lines and in the case of creeping short-circuits. The intact feeders continue to besupplied with 24 V on an absolutely interruption- and reaction-free basis and plant downtimes are minimized. Signaling of the faulty feeder takes place by the LEDs on the device and single-channel signaling. Free function blocks for SIMATIC S7, STEP 7 and TIA Portal as well as SIMOTION CPUs with SIMOTION SCOUT are available for evaluation. The outputs meet the requirements to comply with NEC Class 2. Regardless of the industry or requirement: Siemens offers reliable and efficient power supplies for any plant.

Technical data

ETIM class: Current monitoring relay (EC001440)

Connection

Type of electric connection
Screw connection
Number of contacts as normally closed contact
0
Number of contacts as normally open contact
0
Number of contacts as change-over contact
0

Model/type

With detachable clamps
No
Type of current
UN

Electrical

External power supply required
UN
Voltage type (supply voltage)
UN
Supply voltage AC 50 Hz
UN V
Supply voltage AC 60 Hz
UN V
Supply voltage DC
UN V
Voltage measuring range
UN V
Current measuring range
UN A
Response value amperage 1
UN A
Response value amperage 2
UN A
Single-phase under current possible
UN
Three-phase under current possible
UN
Single-phase overcurrent possible
UN
Three-phase overcurrent possible
UN
Voltage type (operating voltage)
UN
Operating voltage AC 50 Hz
UN V
Operating voltage AC 60 Hz
UN V
Operating voltage DC
UN V
Rated switch current
UN A

Options

Single-phase hysteresis possible
UN
Three-phase hysteresis possible
UN
Contains function DC-voltage under current
No
Contains function DC-voltage overcurrent
Yes
Function DC-current hysteresis
Yes
External current transformer
UN

Setting/control

Min. adjustable delay-on energization time
UN s
Min. adjustable off-delay time
UN s

Operating conditions

Max. permitted delay-on energization time
5 s
Max. permitted off-delay time
UN s

Measurements

Width
72 mm
Height
80 mm
Depth
72 mm

Logistics

Net weight
0.17 kg
Country of origin
Austria
Customs tariff number
85363010

Packaging

PackQuantityGTINGross weightDimensions (L × W × D)
packet140255151549210.201 kg88 × 82 × 77 mm