Skip to content
Eltracore
No photo yet

Siemens

SIMATIC ET 200iSP 4AQ I HART

Manufacturer part no.
EAN
Price on requestAsk us for a quote for this product.

Ordering

Order unit
piece

Description

SIMATIC, electronic module for ET200iSP, 4 AO HART, 4 - 20 mA, for connecting HART field devices, supported HART protocol version 6.0, Ex ib (ia Ga) IIC T4 Gb, Ex ib [ia IIIC Da] IIC T4 Gb, Ex ib [ia] I Mb

Technical data

ETIM class: Fieldbus, decentr. periphery - analogue I/O module (EC001596)

Electrical

Supply voltage AC 50 Hz
UN V
Supply voltage AC 60 Hz
UN V
Supply voltage DC
20.4, 28.8 V
Voltage type (supply voltage)
DC
Power consumption
UN W

Connection

Input, current
UN
Input, resistor
UN
Input, resistance thermometer
UN
Input, thermocouple
UN
Input signal, configurable
UN
Output, current
Yes
Output signal configurable
Yes
Number of analogue inputs
0
Number of analogue outputs
4
Type of electric connection
UN
Fieldbus connection over separate bus coupler possible
Yes

Setting/control

Input, voltage
UN

Other

Resolution of the analogue inputs
UN Bit
Resolution of the analogue outputs
14 Bit
Appendant operation agent (Ex ia)
Yes
Appendant operation agent (Ex ib)
Yes

Options

Output, voltage
No
Analogue inputs configurable
UN
Analogue outputs configurable
Yes
Radio standard Bluetooth
No
Radio standard WLAN 802.11
No
Radio standard GPRS
No
Radio standard GSM
No
Mobile communications standard 3G (UMTS)
No
IO link master
No
System accessory
Yes
Rack-assembly possible
No

Communication

Number of HW-interfaces industrial Ethernet
0
Number of interfaces PROFINET
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces parallel
0
Number of HW-interfaces wireless
0
Number of HW-interfaces USB
0
Number of HW-interfaces other
0
Supporting protocol for EtherCAT
UN
Supporting protocol for TCP/IP
UN
Supporting protocol for PROFIBUS
No
Supporting protocol for CAN
No
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for KNX
No
Supporting protocol for Modbus
No
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
UN
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
No

Protection

Degree of protection (IP)
IP30
Degree of protection (NEMA)
UN
Explosion safety category for gas
UN
Explosion safety category for dust
UN
Certified for UL hazardous location group E (metal dusts)
UN

Mounting/installation

Suitable for rail mounting
Yes
Wall mounting/direct mounting
No
Front built-in possible
Yes

Application

Suitable for safety functions
No

Approval/certification

SIL according to IEC 61508
UN
Certified for UL hazardous location class I
UN
Certified for UL hazardous location class II
UN
Certified for UL hazardous location class III
UN
Certified for UL hazardous location division 1
UN
Certified for UL hazardous location division 2
UN
Certified for UL hazardous location group A (acetylene)
UN
Certified for UL hazardous location group B (hydrogen)
UN
Certified for UL hazardous location group C (ethylene)
UN
Certified for UL hazardous location group D (propane)
UN
Certified for UL hazardous location group F (carbonaceous dusts)
UN
Certified for UL hazardous location group G (non-conductive dusts)
UN

Performance

Performance level according to EN ISO 13849-1
UN

Measurements

Width
30 mm
Height
129 mm
Depth
136.5 mm

Logistics

Net weight
0.337 kg
Country of origin
Germany
Customs tariff number
85389091

Packaging

PackQuantityGTINGross weightDimensions (L × W × D)
packet140191691316810.337 kg162 × 140 × 41 mm