Description

ET 200SP, CM CAN Gateway to CAN or CANopen networks, CAN 2.0A/B, CANopen Manager to CiA301/302, CANopen Slave to CiA301/302, IP20 With SIMATIC ET 200SP, Siemens offers a multifunctional and distributed I/O system, which can be commissioned very simply due to its space-saving design. It is approved for degree of protection IP20 and for installation in a compact control box. The system ensures maximum flexibility because you can quickly and simply replace modules at any time due to the multi hot swapping feature. SIMATIC ET 200SP also offers a wide range of different and fast communication methods. With the integrated MultiFieldbus interface module IM155-6MF, you can use the optimum protocol for your application flexibly at any time because this function supports multiple Ethernet protocols. Installation and service are simplified by a standardized identification system based on equipment labeling plates and color-coded connector assignments. Siemens guarantees a future-proof investment due to integration of innovative and long-life automation products. After all, as industry experts, they are already using tomorrows technologies and thus redefining market standards. Consistent data availability, flexible use cases, and versatile integration options ensure optimum performance of ET 200 products. Communications module for integrating CAN or CANopen devices into the ET 200SP. The accessories available for the ET 200SP range from color-coding plates and equipment labeling plates to labeling strips for the individual modules and thus ensure maximum manageability in the control cabinet.

Technical data

ETIM class: Fieldbus, decentr. periphery - communication module (EC001604)

Electrical

Supply voltage AC 50 Hz
UN V
Supply voltage AC 60 Hz
UN V
Supply voltage DC
19.2, 28.8 V
Voltage type (supply voltage)
DC

Communication

Number of HW-interfaces CAN
UN
Number of HW-interfaces industrial Ethernet
UN
Number of interfaces PROFINET
UN
Number of HW-interfaces RS-232
UN
Number of HW-interfaces RS-422
UN
Number of HW-interfaces RS-485
UN
Number of HW-interfaces serial TTY
UN
Number of HW-interfaces USB
UN
Number of HW-interfaces parallel
UN
Number of HW-interfaces wireless
UN
Number of HW-interfaces other
UN
Supporting protocol for EtherCAT
UN
Supporting protocol for TCP/IP
No
Supporting protocol for PROFIBUS
No
Supporting protocol for CAN
Yes
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for KNX
No
Supporting protocol for Modbus
No
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for SERCOS
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
No

Options

Radio standard Bluetooth
No
Radio standard WLAN 802.11
No
Radio standard GPRS
No
Radio standard eGPRS
No
Radio standard GSM
No
Radio standard LTE
No
Mobile communications standard 3G (UMTS)
No
IO link master
No
System accessory
Yes
Rack-assembly possible
No

Protection

Degree of protection (IP)
IP20
Explosion safety category for gas
UN
Explosion safety category for dust
UN
Certified for UL hazardous location group E (metal dusts)
UN

Model/type

With potential separation
Yes

Connection

Fieldbus connection over separate bus coupler possible
Yes

Mounting/installation

Suitable for rail mounting
Yes
Wall mounting/direct mounting
No
Front built-in possible
No

Application

Suitable for safety functions
No

Approval/certification

SIL according to IEC 61508
UN
Certified for UL hazardous location class I
UN
Certified for UL hazardous location class II
UN
Certified for UL hazardous location class III
UN
Certified for UL hazardous location division 1
UN
Certified for UL hazardous location division 2
UN
Certified for UL hazardous location group A (acetylene)
UN
Certified for UL hazardous location group B (hydrogen)
UN
Certified for UL hazardous location group C (ethylene)
UN
Certified for UL hazardous location group D (propane)
UN
Certified for UL hazardous location group F (carbonaceous dusts)
UN
Certified for UL hazardous location group G (non-conductive dusts)
UN

Performance

Performance level according to EN ISO 13849-1
UN

Other

Appendant operation agent (Ex ia)
No
Appendant operation agent (Ex ib)
No

Measurements

Width
15 mm
Height
73 mm
Depth
58 mm

Logistics

Net weight
0.032 kg
Country of origin
Germany
Customs tariff number
85176200

Packaging

PackQuantityGTINGross weightDimensions (L × W × D)
packet140476181089080.04 kg77 × 70 × 25 mm