Skip to content
Eltracore
No photo yet

Siemens

SIMATIC ET 200eco PN AI 6xU/I + AIQ 2xU/I 8x M12

Manufacturer part no.
EAN
Price on requestAsk us for a quote for this product.
Checking availability…

Ordering

Order unit
piece

Description

SIMATIC ET 200eco PN, AI 6x U/I + AIQ 2x U/I, M12-L, 8x M12, 16-bit resolution, channel diagnostics for wire break and short-circuit, shared device with 2 controllers, prioritized startup, MSI, MSO, MRP, S2 redundancy, IM0...3, multi-fieldbus, PN IO, Ethernet IP, Modbus TCP, degree of protection IP67 / IP69K SIMATIC ET 200eco PN is a compact block I/O system with a PROFINET connection with degree of protection IP65/67 and is therefore a space-saving and future-oriented solution that sets new market standards and also requires very little installation effort. You can quickly and flexibly install and commission the block I/Os in any position. Due to the intelligent design, you can perform installation directly on site on the machine or the assembly line. The very rugged die-cast zinc housing ensures ideal protection in extremely challenging ambient conditions and enables you to use the I/O system at temperatures ranging from -40 °C to +60 °C. A further advantage of the system is its maximum resistance to vibration, dust, oil, and humidity. In the SIMATIC ET 200eco PN, you have a future-oriented and innovative complete solution that can be flexibly configured thanks to the integrated 2-port switches and integrated into line topologies in a plant. The M12-L coded power connectors simplify the power supply concept and also enable higher current-carrying capacity and therefore substantially longer cable lengths in the field without additional power supply cables. Siemens guarantees future-oriented and innovative solutions that help you to move into new business segments with key technologies that have been projected into the future with ET 200 products.​ In addition to digital and analog input and output modules with various characteristics (incl. current, voltage, temperature and resistance measurements), the range of products also encompasses the IO-Link master and a fail-safe module for connecting sensors and actuators up to SIL 3/PLe. If need be, the outputs of the standard modules can also be practically disconnected in a fail-safe manner up to SIL 2.

Technical data

ETIM class: Fieldbus, decentr. periphery - analogue I/O module (EC001596)

Electrical

Supply voltage AC 50 Hz
UN V
Supply voltage AC 60 Hz
UN V
Supply voltage DC
20.4, 28.8 V
Voltage type (supply voltage)
DC
Power consumption
UN W

Connection

Input, current
Yes
Input, resistor
No
Input, resistance thermometer
No
Input, thermocouple
No
Input signal, configurable
Yes
Output, current
Yes
Output signal configurable
Yes
Number of analogue inputs
8
Number of analogue outputs
2
Type of electric connection
Plug-in connection
Fieldbus connection over separate bus coupler possible
No

Setting/control

Input, voltage
Yes

Other

Resolution of the analogue inputs
16 Bit
Resolution of the analogue outputs
16 Bit
Appendant operation agent (Ex ia)
No
Appendant operation agent (Ex ib)
No

Options

Output, voltage
Yes
Analogue inputs configurable
Yes
Analogue outputs configurable
Yes
Radio standard Bluetooth
No
Radio standard WLAN 802.11
No
Radio standard GPRS
No
Radio standard GSM
No
Mobile communications standard 3G (UMTS)
No
IO link master
No
System accessory
Yes
Rack-assembly possible
No

Communication

Number of HW-interfaces industrial Ethernet
0
Number of interfaces PROFINET
1
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces parallel
0
Number of HW-interfaces wireless
0
Number of HW-interfaces USB
0
Number of HW-interfaces other
0
Supporting protocol for EtherCAT
UN
Supporting protocol for TCP/IP
Yes
Supporting protocol for PROFIBUS
No
Supporting protocol for CAN
No
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for KNX
No
Supporting protocol for Modbus
UN
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
Yes
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
Yes

Protection

Degree of protection (IP)
IP65/IP67
Degree of protection (NEMA)
UN
Explosion safety category for gas
Other
Explosion safety category for dust
Other
Certified for UL hazardous location group E (metal dusts)
UN

Mounting/installation

Suitable for rail mounting
Yes
Wall mounting/direct mounting
Yes
Front built-in possible
Yes

Application

Suitable for safety functions
No

Approval/certification

SIL according to IEC 61508
UN
Certified for UL hazardous location class I
UN
Certified for UL hazardous location class II
UN
Certified for UL hazardous location class III
UN
Certified for UL hazardous location division 1
UN
Certified for UL hazardous location division 2
UN
Certified for UL hazardous location group A (acetylene)
UN
Certified for UL hazardous location group B (hydrogen)
UN
Certified for UL hazardous location group C (ethylene)
UN
Certified for UL hazardous location group D (propane)
UN
Certified for UL hazardous location group F (carbonaceous dusts)
UN
Certified for UL hazardous location group G (non-conductive dusts)
UN

Performance

Performance level according to EN ISO 13849-1
UN

Measurements

Width
45 mm
Height
200 mm
Depth
48 mm

Logistics

Net weight
0.812 kg
Country of origin
Germany
Customs tariff number
85389091

Packaging

PackQuantityGTINGross weightDimensions (L × W × D)
packet140476234125260.812 kg198 × 71 × 58 mm