SIMATIC ET 200clean, CM 8x IO-Link + DIQ 4x 24 V DC, 8x M12, 4x port class A + 4x port class B, channel diagnostics, shared device with 2 controllers, MRP, S2 redundancy, IM0...4, multi-fieldbus, PN IO, Ethernet IP, Modbus TCP, degree of protection IP69K The SIMATIC ET 200clean has a special hygienic design that allows you to thoroughly clean 360° in a way that is both easy and efficient. The chemically stable housing is resistant to disinfection and cleaning agents and can also withstand cleaning temperatures of up to 80° and a water pressure of 50 bar. The IP69K rating also guarantees that the device is fully protected against the ingress of dust or other particles. This ensures that even hard-to-reach areas can be cleaned thoroughly and that no contaminants accumulate. These properties make the SIMATIC ET 200clean ideal for use in applications where a high level of cleanliness and hygiene is required. This module allows you to connect up to 8 IO-Link devices, including up to 4 IO-Link actuators with IO-Link, Class B. In addition, up to 4 digital inputs or outputs can be connected. Thanks to its intelligent design, the device can be mounted directly on the machine, saving space in the control cabinet and complex cable routing. The installation and maintenance effort is low, and the device can be put into operation quickly and conveniently via the TIA Portal. Even when replacing the device, you dont need an additional engineering tool, so the SIMATIC ET 200clean not only impresses with its maximum performance and reliability, but also with its high level of user-friendliness.
Technical data
ETIM class: Fieldbus, decentr. periphery - communication module (EC001604)
Electrical
- Supply voltage AC 50 Hz
- UN V
- Supply voltage AC 60 Hz
- UN V
- Supply voltage DC
- 20.4, 28.8 V
- Voltage type (supply voltage)
- DC
Communication
- Number of HW-interfaces CAN
- UN
- Number of HW-interfaces industrial Ethernet
- UN
- Number of interfaces PROFINET
- UN
- Number of HW-interfaces RS-232
- UN
- Number of HW-interfaces RS-422
- UN
- Number of HW-interfaces RS-485
- UN
- Number of HW-interfaces serial TTY
- UN
- Number of HW-interfaces USB
- UN
- Number of HW-interfaces parallel
- UN
- Number of HW-interfaces wireless
- UN
- Number of HW-interfaces other
- UN
- Supporting protocol for EtherCAT
- UN
- Supporting protocol for TCP/IP
- Yes
- Supporting protocol for PROFIBUS
- No
- Supporting protocol for CAN
- No
- Supporting protocol for INTERBUS
- No
- Supporting protocol for ASI
- No
- Supporting protocol for KNX
- No
- Supporting protocol for Modbus
- Yes
- Supporting protocol for Data-Highway
- No
- Supporting protocol for DeviceNet
- No
- Supporting protocol for SUCONET
- No
- Supporting protocol for LON
- No
- Supporting protocol for SERCOS
- No
- Supporting protocol for PROFINET IO
- Yes
- Supporting protocol for PROFINET CBA
- No
- Supporting protocol for Foundation Fieldbus
- No
- Supporting protocol for EtherNet/IP
- Yes
- Supporting protocol for AS-Interface Safety at Work
- No
- Supporting protocol for DeviceNet Safety
- No
- Supporting protocol for INTERBUS-Safety
- No
- Supporting protocol for PROFIsafe
- No
- Supporting protocol for SafetyBUS p
- No
- Supporting protocol for other bus systems
- Yes
Options
- Radio standard Bluetooth
- No
- Radio standard WLAN 802.11
- UN
- Radio standard GPRS
- No
- Radio standard eGPRS
- No
- Radio standard GSM
- No
- Radio standard LTE
- No
- Mobile communications standard 3G (UMTS)
- No
- IO link master
- Yes
- System accessory
- Yes
- Rack-assembly possible
- No
Protection
- Degree of protection (IP)
- UN
- Explosion safety category for gas
- UN
- Explosion safety category for dust
- UN
- Certified for UL hazardous location group E (metal dusts)
- UN
Model/type
- With potential separation
- Yes
Connection
- Fieldbus connection over separate bus coupler possible
- No
Mounting/installation
- Suitable for rail mounting
- Yes
- Wall mounting/direct mounting
- Yes
- Front built-in possible
- Yes
Application
- Suitable for safety functions
- No
Approval/certification
- SIL according to IEC 61508
- UN
- Certified for UL hazardous location class I
- UN
- Certified for UL hazardous location class II
- UN
- Certified for UL hazardous location class III
- UN
- Certified for UL hazardous location division 1
- UN
- Certified for UL hazardous location division 2
- UN
- Certified for UL hazardous location group A (acetylene)
- UN
- Certified for UL hazardous location group B (hydrogen)
- UN
- Certified for UL hazardous location group C (ethylene)
- UN
- Certified for UL hazardous location group D (propane)
- UN
- Certified for UL hazardous location group F (carbonaceous dusts)
- UN
- Certified for UL hazardous location group G (non-conductive dusts)
- UN
Performance
- Performance level according to EN ISO 13849-1
- UN
Other
- Appendant operation agent (Ex ia)
- No
- Appendant operation agent (Ex ib)
- No
Measurements
- Width
- 80 mm
- Height
- 205 mm
- Depth
- 54 mm
Logistics
- Net weight
- 0.337 kg
- Country of origin
- Germany
- Customs tariff number
- 85389091
Packaging
| Pack | Quantity | GTIN | Gross weight | Dimensions (L × W × D) |
|---|---|---|---|---|
| packet | 1 | 4047623415077 | 0.337 kg | — |