SIMATIC ET 200SP CM PROFIBUS DP Master/slave
- Manufacturer part no.
- EAN
Ordering
- Order unit
- piece
Description
SIMATIC DP, CM PROFIBUS DP for ET 200SP CPU module with PROFIBUS DP interface (9-pole D-sub socket) DP master for 125 DP slaves DP slave, With SIMATIC ET 200SP, Siemens offers a multifunctional and distributed I/O system, which can be commissioned very simply due to its space-saving design. It is approved for degree of protection IP20 and for installation in a compact control box. The system ensures maximum flexibility because you can quickly and simply replace modules at any time due to the multi hot swapping feature. SIMATIC ET 200SP also offers a wide range of different and fast communication methods. With the integrated MultiFieldbus interface module IM155-6MF, you can use the optimum protocol for your application flexibly at any time because this function supports multiple Ethernet protocols. Installation and service are simplified by a standardized identification system based on equipment labeling plates and color-coded connector assignments. Siemens guarantees a future-proof investment due to integration of innovative and long-life automation products. After all, as industry experts, they are already using tomorrows technologies and thus redefining market standards. Consistent data availability, flexible use cases, and versatile integration options ensure optimum performance of ET 200 products. Communication modules expand the communication capabilities of the ET 200SP by additional functions or interfaces, such as PtP, IO-Link or AS-i.
Technical data
ETIM class: Fieldbus, decentr. periphery - communication module (EC001604)
Electrical
- Supply voltage AC 50 Hz
- UN V
- Supply voltage AC 60 Hz
- UN V
- Supply voltage DC
- 19.2, 28.8 V
- Voltage type (supply voltage)
- DC
Communication
- Number of HW-interfaces CAN
- UN
- Number of HW-interfaces industrial Ethernet
- UN
- Number of interfaces PROFINET
- UN
- Number of HW-interfaces RS-232
- UN
- Number of HW-interfaces RS-422
- UN
- Number of HW-interfaces RS-485
- UN
- Number of HW-interfaces serial TTY
- UN
- Number of HW-interfaces USB
- UN
- Number of HW-interfaces parallel
- UN
- Number of HW-interfaces wireless
- UN
- Number of HW-interfaces other
- UN
- Supporting protocol for EtherCAT
- UN
- Supporting protocol for TCP/IP
- No
- Supporting protocol for PROFIBUS
- Yes
- Supporting protocol for CAN
- No
- Supporting protocol for INTERBUS
- No
- Supporting protocol for ASI
- No
- Supporting protocol for KNX
- No
- Supporting protocol for Modbus
- No
- Supporting protocol for Data-Highway
- No
- Supporting protocol for DeviceNet
- No
- Supporting protocol for SUCONET
- No
- Supporting protocol for LON
- No
- Supporting protocol for SERCOS
- No
- Supporting protocol for PROFINET IO
- No
- Supporting protocol for PROFINET CBA
- No
- Supporting protocol for Foundation Fieldbus
- No
- Supporting protocol for EtherNet/IP
- No
- Supporting protocol for AS-Interface Safety at Work
- No
- Supporting protocol for DeviceNet Safety
- No
- Supporting protocol for INTERBUS-Safety
- No
- Supporting protocol for PROFIsafe
- No
- Supporting protocol for SafetyBUS p
- No
- Supporting protocol for other bus systems
- No
Options
- Radio standard Bluetooth
- No
- Radio standard WLAN 802.11
- No
- Radio standard GPRS
- No
- Radio standard eGPRS
- No
- Radio standard GSM
- No
- Radio standard LTE
- No
- Mobile communications standard 3G (UMTS)
- No
- IO link master
- No
- System accessory
- Yes
- Rack-assembly possible
- No
Protection
- Degree of protection (IP)
- IP20
- Explosion safety category for gas
- UN
- Explosion safety category for dust
- UN
- Certified for UL hazardous location group E (metal dusts)
- UN
Model/type
- With potential separation
- Yes
Connection
- Fieldbus connection over separate bus coupler possible
- Yes
Mounting/installation
- Suitable for rail mounting
- Yes
- Wall mounting/direct mounting
- No
- Front built-in possible
- No
Application
- Suitable for safety functions
- No
Approval/certification
- SIL according to IEC 61508
- UN
- Certified for UL hazardous location class I
- UN
- Certified for UL hazardous location class II
- UN
- Certified for UL hazardous location class III
- UN
- Certified for UL hazardous location division 1
- UN
- Certified for UL hazardous location division 2
- UN
- Certified for UL hazardous location group A (acetylene)
- UN
- Certified for UL hazardous location group B (hydrogen)
- UN
- Certified for UL hazardous location group C (ethylene)
- UN
- Certified for UL hazardous location group D (propane)
- UN
- Certified for UL hazardous location group F (carbonaceous dusts)
- UN
- Certified for UL hazardous location group G (non-conductive dusts)
- UN
Performance
- Performance level according to EN ISO 13849-1
- UN
Other
- Appendant operation agent (Ex ia)
- No
- Appendant operation agent (Ex ib)
- No
Measurements
- Width
- 35 mm
- Height
- 117 mm
- Depth
- 75 mm
Logistics
- Net weight
- 0.104 kg
- Country of origin
- Germany
- Customs tariff number
- 85176200
Packaging
| Pack | Quantity | GTIN | Gross weight | Dimensions (L × W × D) |
|---|---|---|---|---|