Description
SINAMICS G120 POWER MODULE PM240P-2 UNFILTERED 3AC500-690V+10/-20% 47-63Hz OUTPUT HIGH OVERLOAD: 55KW FOR 150% 60S, 100% 240S; AMBIENT TEMP -20 TO +50 DEG C (HO) OUTPUT LOW OVERLOAD: 75kW FOR 135% 3S, 110% 57S, 100% 240S AMBIENT TEMP -20 TO +40 DEG C (LO) 708x 305x 357 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU FIRMWARE- VERSION V4.7 SP6 HF1 Power Module SINAMICS PM240P-2 Power Module degree of protection IP20 for industrial applications in the process industries for the SINAMICS G120P frequency converter. The Power Modules are available for use in the water/waste water sector and for industrial applications. The new PM240P-2 Power Modules are based on a new hardware platform, which permits a higher power density. The PM240P-2 Power Modules are also suitable for use in safety-related applications. In conjunction with an external tripping unit (e.g. SIRIUS 3SK1), the drive becomes a Safety Integrated Drive with the safety function Safe Torque Off with a Safety Integrity Level of up to SIL 3. A further advantage of the Power Module is its ruggedness because it can also be used in severe ambient conditions, such as temperatures of -10° to 60° and in corrosive environments (resistance to pollution). Enhanced energy efficiency is also achieved with a higher output voltage (98 percent) due to an integrated DC link reactor. This Power Module does not contain an integrated braking chopper and the permissible cable lengths between the converter and the motor are limited. To permit longer cable lengths, output reactors can be connected. The PM240P-2 Power Modules in frame sizes FSD to FSF are available both with and without an integrated Class A line filter in a compact design in a three-phase voltage range of 380 V to 480 V and in a three-phase voltage range of 500 V to 690 V. The PM240P-2 Power Modules with an integrated Class A line filter are suitable for connection to TN systems. The Power Modules without an integrated line filter are suitable for connection to grounded TN/TT and ungrounded IT systems. Shield plates and shield connection kits are available for use when wiring the Control Units and Power Modules to ensure compliance with EMC guidelines. SINAMICS - simply my drive!
Technical data
ETIM class: Frequency converter =< 1 kV (EC001857)
Electrical
- Mains voltage
- 500, 690 V
- Mains frequency
- UN
- Max. output voltage
- UN V
- Nominal output current I2N
- 80 A
- Power consumption
- UN W
- Relative symmetric net voltage tolerance
- -10 %
Connection
- Number of phases input
- 3
- Number of phases output
- 3
- Number of analogue outputs
- UN
- Number of analogue inputs
- UN
- Number of digital outputs
- UN
- Number of digital inputs
- UN
- With PC connection
- UN
Other
- Max. output frequency
- 550 Hz
- Relative symmetric net frequency tolerance
- 5 %
Performance
- Max. output at quadratic load at rated output voltage
- 75 kW
- Max. output at linear load at rated output voltage
- 55 kW
Model/type
- With control element
- UN
- Type of converter
- U converter
Application
- Application in industrial area permitted
- No
- Application in domestic- and commercial area permitted
- No
Communication
- Supporting protocol for TCP/IP
- UN
- Supporting protocol for PROFIBUS
- UN
- Supporting protocol for CAN
- UN
- Supporting protocol for INTERBUS
- UN
- Supporting protocol for ASI
- UN
- Supporting protocol for KNX
- UN
- Supporting protocol for Modbus
- UN
- Supporting protocol for Data-Highway
- UN
- Supporting protocol for DeviceNet
- UN
- Supporting protocol for SUCONET
- UN
- Supporting protocol for LON
- UN
- Supporting protocol for PROFINET IO
- UN
- Supporting protocol for PROFINET CBA
- UN
- Supporting protocol for SERCOS
- UN
- Supporting protocol for Foundation Fieldbus
- UN
- Supporting protocol for EtherNet/IP
- UN
- Supporting protocol for AS-Interface Safety at Work
- UN
- Supporting protocol for DeviceNet Safety
- UN
- Supporting protocol for INTERBUS-Safety
- UN
- Supporting protocol for PROFIsafe
- UN
- Supporting protocol for SafetyBUS p
- UN
- Supporting protocol for BACnet
- UN
- Supporting protocol for other bus systems
- UN
- Number of HW-interfaces industrial Ethernet
- UN
- Number of interfaces PROFINET
- UN
- Number of HW-interfaces RS-232
- UN
- Number of HW-interfaces RS-422
- UN
- Number of HW-interfaces RS-485
- UN
- Number of HW-interfaces serial TTY
- UN
- Number of HW-interfaces USB
- UN
- Number of HW-interfaces parallel
- UN
- Number of HW-interfaces other
- UN
- With optical interface
- UN
Options
- Integrated breaking resistance
- No
Setting/control
- 4-quadrant operation possible
- No
Protection
- Degree of protection (IP)
- UN
- Degree of protection (NEMA)
- UN
Measurements
- Height
- 708 mm
- Width
- 305 mm
- Depth
- 357 mm
Logistics
- Net weight
- 61 kg
- Country of origin
- Germany
- Customs tariff number
- 85044086
Packaging
| Pack | Quantity | GTIN | Gross weight | Dimensions (L × W × D) |
|---|---|---|---|---|
| packet | 1 | 4042948673713 | 74 kg | 745 × 469 × 385 mm |