SINAMICS G120D CU240D-2 PN
- Manufacturer part no.
- EAN
- Series
- SINAMICS G120D
Ordering
- Order unit
- piece
Description
SINAMICS G120D Control Unit CU240D-2 PN PROFINET, STO onboard 6 DI/1 F-DI, 2 DO, 2 AI USB interface SD/MMC card interface HTL encoder interface Degree of protection IP65 Ambient temperature -10 to +50 °C without Power Module SINAMICS CU240D-2 Control Unit for the SINAMICS G120D distributed inverter. The Control Unit performs closed-loop control functions for the inverter. In addition to the closed-loop control, it has additional functions that can be adapted to the particular application through parameterization. The CU240D‑2 Control Units supersede the CU240D Control Units, whereby both versions can be operated with PM250D Power Modules. The Control Units are available in different versions, for example, in CU240D-2 DP, CU240D-2 DP-F, CU240D-2 PN, CU240D-2 PN-F, CU240D-2 PN-F PP (Push Pull: Alternative connection method for the 24 V DC supply voltage and the PN communication) and CU240D-2 PN-F FO (Fiber Optic). The safety function Safe Torque Off (STO) is already integrated into the standard versions of the CU240D‑2 series (CU240D‑2 DP and CU240D‑2 PN). It can be activated either via PROFIsafe or via the safety input. With the fail-safe variants of the CU240D‑2 series (CU240D‑2 DP‑F xx and CU240D‑2 PN‑F xx), the fail-safe SINAMICS G120D inverter provides five safety functions: Safe Torque Off (STO) to prevent the drive from performing active movements, Safe Stop 1 (SS1) for continuous monitoring of a safe braking ramp, Safely Limited Speed (SLS) for preventing dangerous movements when exceeding a speed limit, Safe Direction (SDI) and Safe Speed Monitoring (SSM). An external 24 V DC power supply is required in order to operate the Control Unit. SINAMICS - the integrated drive family for every field of application.
Technical data
ETIM class: Frequency converter =< 1 kV (EC001857)
Electrical
- Mains voltage
- UN V
- Mains frequency
- UN
- Max. output voltage
- UN V
- Nominal output current I2N
- UN A
- Power consumption
- UN W
- Relative symmetric net voltage tolerance
- UN %
Connection
- Number of phases input
- UN
- Number of phases output
- UN
- Number of analogue outputs
- UN
- Number of analogue inputs
- 2
- Number of digital outputs
- 2
- Number of digital inputs
- 6
- With PC connection
- Yes
Other
- Max. output frequency
- UN Hz
- Relative symmetric net frequency tolerance
- UN %
Performance
- Max. output at quadratic load at rated output voltage
- UN kW
- Max. output at linear load at rated output voltage
- UN kW
Model/type
- With control element
- UN
- Type of converter
- UN
Application
- Application in industrial area permitted
- Yes
- Application in domestic- and commercial area permitted
- No
Communication
- Supporting protocol for TCP/IP
- No
- Supporting protocol for PROFIBUS
- No
- Supporting protocol for CAN
- No
- Supporting protocol for INTERBUS
- No
- Supporting protocol for ASI
- No
- Supporting protocol for KNX
- No
- Supporting protocol for Modbus
- No
- Supporting protocol for Data-Highway
- No
- Supporting protocol for DeviceNet
- No
- Supporting protocol for SUCONET
- No
- Supporting protocol for LON
- No
- Supporting protocol for PROFINET IO
- Yes
- Supporting protocol for PROFINET CBA
- No
- Supporting protocol for SERCOS
- No
- Supporting protocol for Foundation Fieldbus
- No
- Supporting protocol for EtherNet/IP
- Yes
- Supporting protocol for AS-Interface Safety at Work
- No
- Supporting protocol for DeviceNet Safety
- No
- Supporting protocol for INTERBUS-Safety
- No
- Supporting protocol for PROFIsafe
- Yes
- Supporting protocol for SafetyBUS p
- No
- Supporting protocol for BACnet
- UN
- Supporting protocol for other bus systems
- No
- Number of HW-interfaces industrial Ethernet
- 2
- Number of interfaces PROFINET
- 2
- Number of HW-interfaces RS-232
- 0
- Number of HW-interfaces RS-422
- 0
- Number of HW-interfaces RS-485
- 0
- Number of HW-interfaces serial TTY
- 0
- Number of HW-interfaces USB
- 1
- Number of HW-interfaces parallel
- 11
- Number of HW-interfaces other
- 0
- With optical interface
- Yes
Options
- Integrated breaking resistance
- UN
Setting/control
- 4-quadrant operation possible
- UN
Protection
- Degree of protection (IP)
- UN
- Degree of protection (NEMA)
- UN
Measurements
- Height
- 208 mm
- Width
- 153 mm
- Depth
- 55 mm
Logistics
- Net weight
- 0.78 kg
- Country of origin
- United Kingdom
- Customs tariff number
- 85371091
Packaging
| Pack | Quantity | GTIN | Gross weight | Dimensions (L × W × D) |
|---|---|---|---|---|
| packet | 1 | 4042948661604 | 0.96 kg | 278 × 208 × 90 mm |