Skip to content
Eltracore

Vemer

ELECTROPROBE EQ2MCR1V03 3TRIM 2DIN 230VA

Manufacturer part no.
EAN
Price on requestAsk us for a quote for this product.

Ordering

Order unit
piece

Description

Electric control liquid level relay for DIN-rail mounting that allows to maintain liquids within set limits (between a maximum and minimun level) and assures the protection of the submerged pumps against dry running. The sensitivity of the relay can be adjusted during the installation in order to suitable it to the conduction value of the liquid. It is also possible to set the intervantion delay time and the operating mode (filling/emptying). Three electrodes are included in the package. The device has a double relay output.

Technical data

ETIM class: (Fill) level monitoring relay (EC001447)

Connection

Type of electric connection
Screw connection
Number of inputs for electrodes
3
Number of contacts as normally closed contact
0
Number of contacts as normally open contact
0
Number of contacts as change-over contact
1

Model/type

With detachable clamps
Yes

Electrical

Voltage type (supply voltage)
AC
Supply voltage AC 50 Hz
195, 253 V
Supply voltage AC 60 Hz
195, 253 V
Supply voltage DC
-, - V
Voltage type (operating voltage)
AC
Operating voltage AC 50 Hz
0, 250 V
Operating voltage AC 60 Hz
0, 250 V
Operating voltage DC
-, - V
Rated switch current
250 A

Setting/control

Min. adjustable operate delay time
0 s
Min. adjustable off-delay time
- s
Response value sensitivity adjustable
Yes

Operating conditions

Max. permitted operate delay time
16 s
Max. permitted off-delay time
- s

Other

Physical measurement principle
Conductive

Options

Cascadable
-

Measurements

Width
36 mm
Height
88 mm
Depth
55 mm

Logistics

Net weight
0.28 kg

Packaging

PackQuantityGTINGross weightDimensions (L × W × D)
piece180079511240470.311 kg80 × 100 × 80 mm